ONC certification compliance

Overview

Organization name

Edenlab

Certified on

Mar 29, 2023

Product name

Kodjin FHIR Server

Product version

3.0.0.

Certification number

15.04.04.3148.Kodj.03.00.0.230330

Disclaimer

This Health IT Module is compliant with the ONC Certification Criteria for Health IT and has been certified by an ONC-ACB in accordance with the applicable certification criteria adopted by the Secretary of Health and Human Services. This certification does not represent an endorsement by the U.S. Department of Health and Human Services.

Features

  • 170.315(d)(1) Authentication, Access Control, and Authorization
  • 170.315(d)(9) Trusted Connection
  • 170.315(d)(10) Audit Actions on Health Information
  • 170.315(d)(12) Encrypt Authentication Credentials
  • 170.315(d)(13) Multi-Factor Authentication
  • 170.315(g)(5) Accessibility-Centered Design
  • 170.315(g)(7) Application Access – Patient Selection
  • 170.315(g)(10) Standardized API for Patient and Population Services
  • 170.315 (b)(10) Electronic Health Information Export
  • 170.315 (g)(4) Quality Management System (ISO 9001:2015)

Standards version advancement process (SVAP) notices

Notice of Intent to Implement 170.215(a)(4): 
HL7 FHIR® Bulk Data Access (Flat FHIR®) (v2.0.0: STU 2) Issued 2021-11-26.Please be advised that Edenlab (Kodjin FHIR Server) has opted to leverage ONC’s SVAP process for the certification criteria at 170.315(g)(10) to adopt the HL7 FHIR® Bulk Data Access (Flat FHIR®) (v2.0.0: STU 2) in its Patient and Population API Services. The adoption of the updated version will provide better forward compatibility and longevity for the APIs certified to this criterion. Because Edenlab (Kodjin FHIR Server) is adopting this version in its initial certification of to the (g)(10) criterion, it is expected that the adoption of the updated version will have no impact on the interoperability of the affected module.

Costs and Conditions

  • The pricing of Kodjin FHIR Server consists of a monthly license fee (billed quarterly or annually) based on the volume of requests per server per month and the number of installations.
  • Each installation contains unlimited clusters of the server (Development, Sandbox, Test, Production, etc.). The limitation is only subject to infrastructure, and the total volume of requests covered by the license.
  • Fees are billed quarterly or annualy (with a discount), and include support and maintenance.
  • Fees are not dependent on data storage volumes, or the number of resources, connected apps, patients, care providers or users, or infrastructure or hardware. Additional fees are subject to the following: additional installations may be required for scaling, fail-over or on-premise installations on multiple sites.
  • All HL7 ® FHIR ® specs supported by the Kodjin FHIR Server are included in the license fee with no additional costs. The HL7 ® FHIR ® specs include, but are not limited to: Rest API, Search, Bulk Data Export, Bulk Data Import, FHIR profiles validations (FHIRPath, structure, cardinality, slicing, binding), Terminology Server, Authorization & Authentication, History, Multi-tenancy, SMART on FHIR spec, UCUM, Subscriptions.

Documentation

All documentation required for evaluating, implementing and hosting the Kodjin FHIR Server is available on the documentation portal for Kodjin FHIR Server.

 

Conditions

  • No limitations or restrictions apply for using Kodjin FHIR Server, other than defined in the license for scaling.

  • Edenlab will not maintain any relationship with end-users, e.g. customers or users of our customers, patients or third-party app developers, of the FHIR Server API.

  • In accessing data, there are no limitations or restrictions set by Edenlab and Kodjin.

  • Edenlab does not have access to any PHI. Hosting and infrastructure are handled by the customer.

  • Our customers are free to market, offer, and distribute products and services related to Kodjin FHIR Server within the scope of the license (the number of production installations and volume of requests).

  • Edenlab guarantees the required support, maintenance, documentation to enable the implementation, deployment and use of Kodjin FHIR Server.The terms and conditions of the Kodjin FHIR server apply.

CQMS tested

None

Additional software

None

Additional fees

None

Certificate

 

Let`s chat

We would be glad to share more details about our enterprise-level FHIR software solutions and other cases based on the HL7 FHIR standard.

    Your form has been submitted successfully

    We will contact your shortly

    Kodjin White Paper

    Please leave your email to get Kodjin White Paper

      By downloading files from this site you agree to the Policy

      The Kodjin White Paper has been successfully sent to your email

      We have sent a copy to your email

      Back to website content